What to Ask Before You Buy a Fume Hood

Fume hoods are a necessity, but can also be a costly investment for many laboratories. When purchasing a fume hood, it’s important to make sure that you’re getting the right hood for your lab and your budget.

TL;DR: Questions to ask before you buy

  • What chemicals will I be using in the hood?
  • Do I need a ducted or ductless fume hood?
  • What size hood fits my work and my space?
  • What is required for installation?
  • What will it cost to buy, install, and run?
  • Does it come with an airflow monitor, and will it work with my building’s air system?

 


What chemicals will you be using in the hood?

Start here, because your chemical list drives almost every other decision: the type of hood, the liner material, and even whether a ductless hood is an option at all. Write down every chemical you expect to use, roughly how much, and how often. If you work with strong acids, perchloric acid, or radioisotopes, flag those, because they usually call for a specialty hood.

Which type of fume hood do you need?

There are different types of fume hoods. Each one affects price, installation, and what you can safely do inside it.

Ducted vs. ductless fume hoods

A ducted fume hood pulls air out of the lab and exhausts it outside through ductwork and a blower. It handles the widest range of chemicals, but it takes more work to install.

A ductless fume hood runs air through carbon or HEPA filters and sends it back into the room. It’s cheaper and easier to set up, but it only works for specific, known chemicals in limited amounts, and the filters need to be replaced on a schedule. If your chemical list is long or changes often, a ducted hood is usually the safer bet.

Benchtop vs. floor-mounted (walk-in) hoods

Benchtop hoods sit on a base cabinet or table and cover most everyday lab work. Floor-mounted hoods, often called walk-in hoods, go all the way down to the floor so you can roll in large equipment, carts, or tall setups.

walk-in fume hood

What does your building need to install a fume hood?

Before you order, check the fume hood installation requirements: exhaust capacity, makeup air, electrical service, and any water, gas, or vacuum lines you want run to the hood. How involved the install gets depends mostly on one choice: ducted vs. ductless fume hood. A ducted hood needs exhaust ductwork and a blower, while a ductless hood filters the air and returns it to the room.

A ductless hood can often be set up by your own facilities team, since it mostly needs a sturdy surface and an outlet. A ducted hood is a bigger job that usually brings in a few different trades.

Exhaust and makeup air

A ducted hood needs a duct run to the outside, usually through the roof, and a blower to pull the air. An HVAC or mechanical contractor typically handles this. Every bit of air the hood exhausts has to be replaced, so your building may also need added makeup air to keep the room balanced.

Electrical

Fume hoods need power for the light, the blower, any monitors or alarms, and outlets inside the hood. An electrician should confirm your circuits can handle it. See our post on fume hood voltage requirements for specifics.

Water, gas, and vacuum lines

If you want a cup sink, gas, or vacuum at the hood, you’ll need a plumber or lab services contractor to run those lines. Decide this before installation, because adding services later is a lot harder.

 

How much does a fume hood cost?

Laboratory fume hood cost depends mostly on size, type, and liner material. The cost of an average 6-foot fume hood is dependent on many factors. According to industry professionals, the “rule of thumb” is anywhere from $1,200 to $2,500 per linear foot. 

Factors such as hood dimensions, special features, technology, and add-ons are all considered when pricing a hood. Different procedures may require certain hoods. For example, a fume hood that is designed for spill containment will be priced differently than a fume hood made for highly hazardous substances.

However, not only do you have to factor in the cost of the hood, but you also need to consider the installation and operational costs. Here’s a look at how much a fume hood costs in more detail.

Installation Costs

Installation cost comes down to how far the hood is from an exhaust point. The main drivers are the length of the duct run, whether you need a new roof penetration, the blower, any added makeup air, the base cabinet or work surface, and connecting water, gas, or vacuum lines.

Energy and Operating Costs

The biggest operating cost isn’t the electricity for the light or the fan. It’s the heated or cooled room air the hood pulls out, and how much it pulls depends on its fume hood face velocity, the speed of air moving into the front opening. That’s why fume hoods are one of the biggest energy users in most labs. A few ways to bring that cost down:

  • Close the sash when you’re not working. On a VAV system, a lower sash means less exhaust air and less conditioned air thrown away. Here’s more on what a fume hood sash does.
  • Use occupancy sensors. They lower airflow automatically when nobody’s standing at the hood.
  • Look at exhaust heat recovery. These systems capture heat from the exhaust air to pre-condition incoming air.
  • Place the hood away from doors, vents, and walkways. Cross drafts hurt containment, which can push you toward higher airflow than you’d otherwise need.
  • Manage blowers across multiple hoods. Labs with several hoods can often share or stage blowers instead of running each one full time. Read more about choosing the right fume hood blower.

For more ideas, check out our tips on saving energy with your fume hood

shut the sash

What safety controls come with a fume hood?

Fume hoods may be required to have airflow monitors. However, only some fume hoods come equipped with them. If the fume hood you purchase does not have an airflow monitor, you will have to purchase one separately. Airflow monitors can cost anywhere from a few hundred to a few thousand dollars.

There are two major types of airflow monitors: analog and digital. If the fume hood is on a constant air volume (CAV) system, then you can use either a digital or analog airflow monitor provided by the hood manufacturer. However, if the hood is on a variable air volume (VAV) system, then the airflow monitor needs to come from the VAV supplier so that it can be properly calibrated to the VAV system.

Ready to find the right fume hood?

Purchasing a fume hood is a great investment, and the safety benefit is priceless. 

If you are in the process of purchasing a fume hood, contact National Laboratory Sales, and we’ll help you figure out what fits your lab and your budget.